QA / QC ProtocolASHRAE Standard 90.1

ASHRAE 90.1 Baseline Building Verification:
A Guide to Model Integrity

"In the world of high-performance building design and LEED certification, the accuracy of the Baseline Building (B) model is paramount."

Unlike the Proposed Design, which reflects your specific architectural choices, the Baseline Design is a theoretical reference point strictly defined by code—specifically ASHRAE Standard 90.1 (Section 11 or Appendix G).

At AECO, we utilize a rigorous verification framework to ensure that this fictional reference building is configured correctly. This checklist outlines the critical inputs we validate to guarantee that your energy savings are calculated against a precise, code-compliant standard.

Expert Insight: The Verification Distinction

Proposed Design Checks

Rely on Design Documents. We verify that the model matches the architectural and mechanical drawings of what will actually be built.

Baseline Design Checks

Rely on Code Rules. We verify that the model matches the rules of ASHRAE 90.1. This ensures a standardized yardstick.

Core Verification Areas

I. General Compliance & Model Integrity

ParameterVerification Task
Model ConfigurationVerify approved simulation software, correct Climate Zone, and weather file match Proposed Design.
Unmet Load HoursConfirm UMLH < 300 hours and match simulation output reports.
Simulation MatchValidate annual energy use/cost outputs align with generated reports.

II. Building Envelope (U-Factors & SHGC)

ParameterVerification Task
Opaque Surface PropertiesVerify U-factors for roofs, walls, floors based on assembly type and climate zone tables.
Fenestration Area (WWR)Check WWR classification and capping (e.g., 40% for Appendix G) and proportional distribution.
Fenestration PropertiesVerify window U-factors and SHGC meet minimum code requirements.
Infiltration & ReflectanceConfirm air leakage rates and roof reflectivity (typ. 0.30) match compliance path rules.

III. Interior Lighting (LPD)

ParameterVerification Task
LPD EstablishmentVerify Lighting Power Density aligns with allowable maximums (Building Area vs Space-by-Space).
Lighting ControlsEnsure NO automatic daylighting/occupancy controls are modeled unless mandatory.

IV. HVAC Systems

ParameterVerification Task
System Type SelectionVerify System Type (e.g. PSZ-AC, VAV) matches Table G3.1.1A based on building metrics.
Sizing & CapacitiesCheck sizing runs and mandatory oversizing (15% cooling, 25% heating).
Efficiencies & AirflowConfirm equipment efficiencies cover minimum standards; airflow based on delta-T.

Need a Third-Party Review?

AECO provides independent verification to ensure your LEED energy models are audit-ready.

Request a Peer Review